AUTOMATED GAS ANALYSER
ANOI 5

The Gas Analyser is a compact and independent equipment used to measure exhaust gases of gasoline vehicles.
This is a 5 Gas Analyser CO, CO2, HC, O2 y NOX (optional), and Lambda coefficient.
It is possible to attach a TUR II module, it ia an universal (both gasoline or diesel ) RPM and oil temperature meter.
A 5000 vehicle database is available, you can match manufacturer's values with real exhaust values taken during the tests.
Test results can be displayed on a screen, printed or stored in a database
TECHNICAL FEATURES
|
ANOI 5 Measuring chamber:
CO: 0-15% vol Res. 0.001% vol CO2: 0-20% vol Res. 0.01% vol HC: 0-2000 ppm vol Res. 1ppm vol O2: 0-25% vol Res. 0.01% vol NOx:0-5000 ppm vol Res. 1 ppm vol (Optional) Lambda:0.5-1.7 Res. 0.001
- Operation temperature: -12º to 50ºC
- Measured gas suction:
Nominal flow: ~4.0 l/min. Drainage flow: ~3 l/min.
- Condensate discharge: Continuous and automatic
- Heating time: max 10 minutes .
- Regulations: UNE 82501
ANOI 5 Software:
- Wifi ready cabinet for wireless communication with external gadgets (tablet, PDA, etc), from where you can control all software options.
- Real time gas data visualisation.
- Real time analog or digital oil temperature and RPM values visualisation.
- Simultaneous manufacturer's and test's value visualisation, if available.
- LAMBDA coefficient visualisation.
- Up to 6 tests per vehicle can be stored in RAM.
- Data test can be saved in the database.
- Data tests saved in the database can be printed or viewed.
- Customer, vehicle and test management.
- NOX Kit connection available.
- TUR II connection available.
|
NOx Kit (optional):
- Nominal measurement range : 0 / 5000 ppm
- In board filtering: To avoid SOx gas flow effect.
- Average life expectancy: 2 years.
- Output signal: 0.05 ± 0.01 μA / ppm
- Resolution: 1 ppm
- temperature range: From -20ºC to +55ºC
- Pressuer range: Atmospheric ±10%
- Pressure coefficient: 0.01% señal / mBar
- Response time at 95ºC: ≤ 5.5 Seconds
- Relative humidity Range: 0 - 12 ppm
- Typical base line range (Clean air): 0 to 99% without condensates
- Maximum zero variation (+20ºC to + 40ºC): Equivalent to 30 ppm
- Weight: 32 gr
- Storage average life: Six months in CLT container
- Storage temperature:Avoid extreme cold or hot exposure.
RPM and Temperature measuring equipment (TUR-II):
- RS232 data transmission ready.
- Visualization display.
- Measuring characteristics:
- Cylinder number selection option. - Stroke engine number selection option.
- Power source: 10 to 28 V DC .
- With the vehicle's own battery.
- With a stabilized power supply.
- Consumption 0.5 A DC
- Equipment working room temperature: 5ºC - 40ºC
- Dimensions 200x45x100 mm.
- Weight: 0.5 kg.
- TEMPERATURE CHARACTERISTICS:
- Measuting range: from 15ºC to 200ºC
- Resolution: 1
- - Type of probe: PT100
- VOLUTION CHARACTERISTICS:
- Range of measures: 300 - 9990 r.p.m.
- Resolution: 10
Type of measure : Vibration
|
ACCESSORIES:
- TUR II: Temperature meter and universal rpm counter.
- NOx Kit.
- TERMOFRA: Infra-red thermometer.